0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
THD 10-4812WIN

THD 10-4812WIN

  • 厂商:

    TRACOPOWER

  • 封装:

    DIP9 模块

  • 描述:

    隔离模块 直流转换器 1 输出 12V 833mA 18V - 75V 输入

  • 数据手册
  • 价格&库存
THD 10-4812WIN 数据手册
DC/DC Converter THD 10WIN Series, 10 Watt • • UItra wide 4:1 input voltage range • • High efficiency up to 87% • • • I/O isolation 1’500 VDC Internal EMI-filter meets EN 55032, Class A without external components Operating temperature range –40°C to +85°C UL 62368-1 IEC 62368-1 The THD 10WIN series is designed for an optimized cost/performance ratio of DC/DC converters with output power of 10 Watt. They come with an internal EMI-filter to meet EN 55032, class A without external components. General features like no minimum load requirement, overload protection and high efficiency make these converters easy to design in. With the popular DIP-24 standard package they are also a drop in replacement for many cost critical applications. Overload protection 3-year product warranty Models Order Code Input Voltage Range THD 10-2410WIN THD 10-2411WIN THD 10-2412WIN THD 10-2413WIN THD 10-2415WIN THD 10-2422WIN THD 10-2423WIN THD 10-4810WIN THD 10-4811WIN THD 10-4812WIN THD 10-4813WIN THD 10-4815WIN THD 10-4822WIN THD 10-4823WIN www.tracopower.com 9 - 36 VDC (24 VDC nom.) 18 - 75 VDC (48 VDC nom.) Output 1 Output 2 Vnom Imax 3.3 VDC 5.1 VDC 12 VDC 15 VDC 24 VDC +12 VDC +15 VDC 3.3 VDC 5.1 VDC 12 VDC 15 VDC 24 VDC +12 VDC +15 VDC 2'700 mA 2'000 mA 833 mA 666 mA 416 mA 416 mA 333 mA 2'700 mA 2'000 mA 833 mA 666 mA 416 mA 416 mA 333 mA September 20, 2023 Vnom Efficiency Imax –12 VDC –15 VDC 416 mA 333 mA –12 VDC –15 VDC 416 mA 333 mA typ. 86 % 85 % 87 % 87 % 87 % 87 % 87 % 86 % 85 % 87 % 87 % 87 % 87 % 87 % Page 1 / 4 THD 10WIN Series, 10 Watt Input Specifications Input Current - At no load 24 Vin models: 48 Vin models: 24 Vin models: 48 Vin models: 24 Vin models: 48 Vin models: 24 Vin models: 48 Vin models: 24 Vin models: 48 Vin models: 24 Vin models: 48 Vin models: 24 Vin models: 48 Vin models: - At full load Surge Voltage Start-up Voltage Under Voltage Lockout Reflected Ripple Current Recommended Input Fuse Input Filter 30 mA typ. 20 mA typ. 470 mA typ. 240 mA typ. 50 VDC max. (1 s max.) 100 VDC max. (1 s max.) 7 VDC min. / 8 VDC typ. / 9 VDC max. 14 VDC min. / 16 VDC typ. / 18 VDC max. 8.5 VDC max. 17 VDC max. 40 mAp-p typ. 30 mAp-p typ. 2'000 mA (slow blow) 1'000 mA (slow blow) (The need of an external fuse has to be assessed in the final application.) Internal Pi-Type Output Specifications Voltage Set Accuracy Regulation - Input Variation (Vmin - Vmax) - Load Variation (0 - 100%) Ripple and Noise Capacitive Load - Voltage Balance (symmetrical load) - 20 MHz Bandwidth - single output 3.3 Vout models: 5.1 Vout models: 12 Vout models: 15 Vout models: 24 Vout models: 12 / -12 Vout models: 15 / -15 Vout models: - dual output Minimum Load Temperature Coefficient Short Circuit Protection Output Current Limitation Transient Response ±2% max. 1% max. 1% max. 1.2% max. 1.2% max. (Output 1) 1.2% max. (Output 2) dual output models: 2% max. single output models: dual output models: single output models: dual output models: - Response Deviation - Response Time 100 mVp-p max. 1'000 µF max. 1'000 µF max. 470 µF max. 330 µF max. 150 µF max. 220 / 220 µF max. 150 / 150 µF max. Not required ±0.02 %/K max. Continuous, Automatic recovery 150% typ. of Iout max. 3% typ. / 5% max. (75% to 100% Load Step) 300 µs typ. / 600 µs max. (75% to 100% Load Step) Safety Specifications Safety Standards - IT / Multimedia Equipment - Certification Documents Pollution Degree CSA-C22.2, No. 60950-1 EN 60950-1 EN 62368-1 IEC 60950-1 IEC 62368-1 UL 60950-1 UL 62368-1 www.tracopower.com/overview/thd10win PD 2 All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. www.tracopower.com September 20, 2023 Page 2 / 4 THD 10WIN Series, 10 Watt EMC Specifications EMI Emissions EMS Immunity - Conducted Emissions - Electrostatic Discharge - RF Electromagnetic Field - EFT (Burst) / Surge - Conducted RF Disturbances EN 55032 class A (internal filter) EN 55024 (IT Equipment) EN 55035 (Multimedia) Air: EN 61000-4-2, ±8 kV, perf. criteria A Contact: EN 61000-4-2, ±6 kV, perf. criteria A EN 61000-4-3, 10 V/m, perf. criteria A EN 61000-4-4, ±2 kV, perf. criteria A EN 61000-4-5, ±1 kV, perf. criteria A Ext. input component: 220 μF, 100 V EN 61000-4-6, 10 Vrms, perf. criteria A General Specifications Relative Humidity Temperature Ranges Power Derating - Operating Temperature - Case Temperature - Storage Temperature - High Temperature Cooling System Remote Control - Voltage Controlled Remote - Off Idle Input Current - Remote Pin Input Current Altitude During Operation Switching Frequency Insulation System Isolation Test Voltage Isolation Resistance Isolation Capacitance Reliability Washing Process Housing Material Base Material Potting Material Pin Material Pin Foundation Plating Pin Surface Plating Housing Type Mounting Type Connection Type Footprint Type Soldering Profile Weight - Input to Output, 60 s - Input to Output, 500 VDC - Input to Output, 100 kHz, 1 V - Calculated MTBF 95% max. (non condensing) –40°C to +85°C +105°C max. –50°C to +125°C 2.86 %/K above 70°C See application note: www.tracopower.com/overview/thd10win Natural convection (20 LFM) On: 3.5 to 12 VDC or open circuit Off: 0 to 1.2 VDC or short circuit Refers to 'Remote' and '-Vin' Pin 10 mA max. -0.5 to 0.5 mA 6'000 m max. 300 - 360 kHz (PWM) 330 kHz typ. (PWM) Functional Insulation 1'500 VDC 1'000 MΩ min. 1'000 pF typ. 1'500 pF max. 1'000'000 h (MIL-HDBK-217F, ground benign) According to Cleaning Guideline www.tracopower.com/info/cleaning.pdf Metal Non-conductive Plastic (UL 94 V-0 rated) Silicone (UL 94 V-0 rated) Copper Alloy (C6801) Nickel (2.5 µm min.) Gold (75 - 125 nm), glossy Metal Case PCB Mount THD (Through-Hole Device) DIP24 Lead-Free Wave Soldering 260°C / 10 s max. 17.3 g All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. www.tracopower.com September 20, 2023 Page 3 / 4 THD 10WIN Series, 10 Watt Environmental Compliance - REACH Declaration www.tracopower.com/info/reach-declaration.pdf REACH SVHC list compliant REACH Annex XVII compliant www.tracopower.com/info/rohs-declaration.pdf Exemptions: 7a (RoHS exemptions refer to the component concentration only, not to the overall concentration in the product (O5A rule).) b791aa3f-0104-4139-9ff5-537e1ec921bd - RoHS Declaration - SCIP Reference Number Supporting Documents Overview Link (for additional Documents) www.tracopower.com/overview/thd10win Outline Dimensions 9 11 Pinout 22 16 14 2.54 2.54 15.24 (0.600) (0.100)(0.100) 4.1 5.08 4.5 (0.200) (0.18) Single Dual 1 Remote On/Off Remote On/Off 2 –Vin (GND) –Vin (GND) 3 –Vin (GND) –Vin (GND) 9 No pin Common –Vout 11 NC 14 +Vout +Vout 16 –Vout Common 22 +Vin (Vcc) +Vin (Vcc) 23 +Vin (Vcc) +Vin (Vcc) (0.16) Ø0.5 (Ø0.02) Pin NC: Not connected 10.2 (0.40) 23 2.54 Bottom View 20.3 (0.80) 3 15.22 (0.599) 2 (0.100) 1 31.8 (1.25) Dimensions in mm (inch) Tolerances: x.x ±0.50 (x.xx ±0.02) Tolerances: x.xx ±0.25 (x.xxx ±0.01) Pin diameter tolerance: x.x ±0.05 (x.xx ±0.002) © Copyright 2023 Traco Electronic AG Specifications can be changed without notice. www.tracopower.com Rev. September 20, 2023 Page 4 / 4
THD 10-4812WIN 价格&库存

很抱歉,暂时无法提供与“THD 10-4812WIN”相匹配的价格&库存,您可以联系我们找货

免费人工找货